Learn to match a COA to its lot, distinguish identity and assay from chromatographic purity, interpret water and salt content, and recognise the limits of analytical evidence.

ACUK EDITORIAL RESEARCH · REVIEWED 2026-11-20 · EDUCATIONAL INFORMATION, NOT MEDICAL ADVICE

1. Match the certificate to the lot

A certificate of analysis (COA) reports analytical findings for an identified batch of material. Start by matching the LOT or batch number on the container to the certificate, then check the material name and stated chemical form. A certificate for another lot is not evidence about the container in front of you. ICH Q7 provides a useful reporting benchmark: material name, batch number and release date should be recorded. [1]

Check the issuer, document date, authorisation and any expiry or retest date. If material has been repackaged, look for a traceable link to the original batch and report. A familiar logo or matching product name alone does not establish authenticity; unresolved discrepancies need clarification from the issuer. [1]

2. Separate the result from the acceptance limit

A specification is a defined set of tests, analytical procedures and acceptance criteria. The criterion describes what is acceptable; the result describes what was found. For a numerical test, look for the measured value and units rather than only the word 'Pass'. ICH Q7 recommends reporting acceptance limits alongside numerical results where the test produces numbers. [1] [2]

Read each row separately. Passing an identity test does not mean every impurity has been measured. Specifications address selected quality attributes rather than providing complete characterisation, so a missing test must not be interpreted as a favourable result. [2]

3. Ask what supports identity

Identity asks whether the sample is consistent with the stated substance. Look for the identification method and its expected observation or reference comparison. ICH Q6A says an identity test should distinguish closely related compounds likely to be present; a single chromatographic retention time is not sufficiently specific on its own. Retention time means when a component emerges from the separation column. [2] [4]

Combined methods, such as liquid chromatography with mass spectrometry, can provide complementary evidence. However, the scope of the identity claim still depends on the procedure's ability to distinguish plausible alternatives. For a salt, identification should also address the relevant ions, not just the principal molecule. [2]

4. Distinguish assay from chromatographic purity

Assay measures the content of the specified substance. Chromatographic purity may instead be an area percentage: the main peak's area divided by the total included peak area. A chromatogram is a plot of detector response during separation. These are different measurements, even when both use high-performance liquid chromatography, or HPLC. Check the calculation behind any percentage labelled 'purity'. [2] [4]

An HPLC area percentage is not automatically the substance's percentage by mass in the whole powder. Components can produce different detector responses, unresolved components can share a peak, and reporting rules can exclude small peaks or solvent signals. Consequently, a high area percentage does not by itself establish content or exclude everything the method cannot detect. [4]

5. Account for water and salt content

Water, residual solvents and counterions can contribute to a material's mass without being represented by its main chromatographic peak. A counterion is an oppositely charged ion accompanying a charged molecule in a salt. It may be part of the declared chemical form rather than an unintended contaminant. Ask whether content is reported as received, on a dry basis, or using another stated correction. [2] [3]

This matters particularly for peptide materials. A BIPM comparison calculated peptide mass fraction using separate measurements of related impurities, water, counterions and volatile solvents. That study demonstrates why chromatographic purity and whole-material content should not be substituted for each other; its values cannot be assumed for another material. For water testing, ICH Q6A prefers a water-specific method such as Karl Fischer titration when appropriate. [2] [3]

6. Read the method and its uncertainty

Look for a method reference, not just an instrument acronym. For chromatography, separation conditions, detector settings, reference standards and integration rules affect interpretation. System suitability checks whether the analytical system performs adequately for that procedure; a clean-looking trace is not a substitute for those checks. [4]

Measurement uncertainty describes the doubt associated with a numerical estimate. If uncertainty is reported, read its stated basis before comparing close results. If it is absent, do not treat extra decimal places as proof of accuracy: the BIPM peptide comparison found that impurity identification and quantification choices affected content estimates. [3]

7. Recognise what a COA cannot establish

A chemical identity or purity result does not establish sterility, endotoxin status or biological activity unless those attributes have their own appropriate evidence. Nor does one batch result establish stability after different storage conditions. Stability monitoring and representative sampling are separate parts of quality assessment. [1] [2] [3]

A COA is analytical evidence, not proof of clinical safety, regulatory approval or suitability for every experiment. Read it against the actual laboratory question: does this lot have the relevant measured attributes, using suitable methods? The pharmaceutical standards cited here explain reporting principles; they do not certify any supplier or research material. [1] [2]

References

  1. ICH Q7: Good Manufacturing Practice Guide for Active Pharmaceutical Ingredients — sections 11.4–11.6
  2. ICH Q6A: Specifications — Test Procedures and Acceptance Criteria for New Drug Substances and New Drug Products: Chemical Substances
  3. BIPM CCQM-K115: Key Comparison Study on Peptide Purity — Synthetic Human C-Peptide, Final Report, January 2017
  4. The International Pharmacopoeia, Thirteenth Edition, 2025: 1.14.1 Chromatography